Byk 1006 Fugaflex 20 Kg
Cement and Polymer Based, High Performance, Water Repellent, Silicone Additive, Flexible Joint Filler
BYK 1006 FUGAFLEX, Cement and polymer based, flexible, water repellent, silicone added. It is used in the joints of materials such as ceramic, porcelain, granite and marble and is not affected by temperature differences, water and vibration.
In compliance with TS EN 13888 – CG2WA standards.
CG : Cement Based Grouting
2 : Additional Features Improved
W : Reduced Water Absorption
A : High Wear Resistance
Fields of Application
• For indoor and outdoor applications, vertical and horizontal applications,
• Hotel, hospital, shopping center, housing etc.
• In all wet areas,
• In swimming pool and drinking water tank,
• It is used in all kinds of decorative applications.
Advantages
• Mixed only with water.
• Water repellent.
• It is resistant to mold and dirt formation.
• Resistant to impacts, vibrations and detergents.
• Easy to prepare and apply,
• 3-15 mm. Suitable for width-bearing joints,
• Resistant to water and frost,
Technical Features
Structure of the Material |
Special cement, mineral fillings, polymers additive |
Density |
1,85 kg/lt |
Colour |
White and Colors |
Stress Strength |
≥ 16 N/mm² |
Flexural Strength |
≥ 4 N/mm² |
Flexural Strength after freeze |
≥ 2.5 N/mm² |
Water Absorption after 30 min |
≤ 2 gr |
Water Absorption after 4 hours |
≤ 5 gr |
Wear Strength |
<1000 mm3 |
Application Thickness |
3-15 mm |
Application Surface Temperature |
+5ºC / +35ºC |
Service Temperature |
-40ºC / +80ºC |
Initial Curing Time |
3–5 minutes |
Workable Time |
1 hour |
Opening the Traffic |
24 hours |
The values above are given for +23°C and 50% relative humidity. While higher temperatures shorten the period, lower temperatures extend it
Application Procedure
Preparation of the Substrate
Making strength of adhesive should be expected before starting joint sealant application. 48 hours of waiting time is generally sufficient. The grout in the joints should be cleaned and the joints should be emptied. Joints of highly absorbent materials must be moistened before filling.
Mixing
Clean water as described on the package is put into a clean mixing bowl. When the BYK 1006 FUGAFLEX bag is opened slowly into the water, it is about 3 minutes until it is homogenous with the 400-600-speed mixing drill. Mixed. The material should not remain in the pellet. After resting the material for 3 minutes again 1 min. ready for application by mixing. Different water ratios and different forms of mixing may cause unwanted color differences.
Mixing Ratio
For 20 kg/1 bag of BYK 1006 FUGAFLEX approximately 6,00-6,60 lt of water should be used. For 10 kg/1 bag of BYK 1006 FUGAFLEX approximately 3,00-3,30 lt of water should be used. For 5 kg/1 bag of BYK 1006 FUGAFLEX approximately 1,50-1,65 lt of water should be used.
Application
Consumption
Variable
Consumption Table for Cement Based Grouting (Depth: 8 mm) Values are given in gr / m2.
Ceramic Dimensions |
2 mm |
3 mm |
4 mm |
5 mm |
6 mm |
10x10 | 550 | 800 | 1100 | 1350 | 1600 |
10x20 | 400 | 650 | 850 | 1050 | 1250 |
15x15 | 450 | 650 | 900 | 1000 | 1350 |
15x20 | 300 | 500 | 650 | 800 | 1000 |
20x20 | 300 | 450 | 600 | 750 | 900 |
20x25 | 275 | 400 | 500 | 700 | 800 |
20x30 | 250 | 375 | 500 | 600 | 750 |
30x30 | 200 | 300 | 400 | 500 | 600 |
Package
Cleaning of Application Tools
Watch Points
• In BYK 1006 FUGAFLEX application, suitable temperatures should be expected if ambient and surface temperature are below
+ 5 ° C or above + 35 ° C. It should not be applied in extremely hot, rainy or very windy weather.
• In outdoor applications, for the first 24 hours should be protected from sun, rain, wind and freezing.
• Working and reaction times in grouting mortars are affected by air temperature, humidity and floor temperatures.
• High temperatures accelerate hydration and the working time is shortened accordingly. Low temperatures slow down hydration and thus extend the working time. For the material to be completed, the floor temperature and ambient temperature to be applied must not fall below the minimum permissible temperature.